Standard Features of the Concept 100
*Programmable (+) or (-) require relays.
System Components
The Concept 100 installation kit contains the following components:
One Prewired 22-pin connector harness One Extended Range Receiver
One Prewired 4-pin connector harness One Insignia Siren
One Concept 100 Control Unit One PlainView 2 Coded Valet Switch
One Hardware Kit One Prewired LED
One Glass Tampering Sensor One User’s Manual
One Dual Zone Piezo Sensor Two Clifford Window Decals
Two Remote Transmitters
Con cept 100/199 1
n Lifetime Warranty
n His & Hers Remote Controls
n ACG™ 2 (Anti-CodeGrabbing™)
n Extended Range Receiver
n Audible Low Transmitter Battery Warning
n Built-In 2-Point Immobilizer
n Optional Wireless Immoblizer
n FACT — False Alarm Control and Test
n Remote Siren Silencing
n Dual Zone Piezo Sensor
n Glass Tampering Sensor
n Dual-Mode “Chirp” Silencing
n Patented UltraSecure Coded Valet Mode
n Optional DataPort™ Interface to Your Own PC
n Point-and-Click Feature Programming
n Complete System Diagnostics At-A-Glance
n High-Output Insignia Siren
n Remote Door Locking/Unlocking*
n Remote Panic with Smart Locking/Unlocking*
n Built-In Dual Parking Light Flasher with Onboard Relay
n Remote Controlled Courtesy Lighting Output
n Remote Keyless Entry and Accessory Activation Even in
Valet Mode
n Patented Smart AutoTesting™
n Smart Remote Trunk Release
n User-Selectable AutoArming
n AutoArm & Lock with Visual Indication
n Instant AutoArm Bypass
n Patented Malfunction AutoBypass™ with
AutoReMonitoring
n Patented SmartPowerUp™ 2
n Multiple Vehicle Control with Same Remote
nEight-Event TotalRecall
n Patented Smart Prior Intrusion Attempt Alert
n Patented Remote Control Code Learning and
MultiRemote Recognition
nClear All Remotes
n High-Luminescence LED Status Indicator with Automatic
Battery-Saving Mode
n Full-Time SecureAccess™ Programming
n Advanced CMOS Microcomputer
n Pre-Loomed Wiring
n 2 Accessory Outputs with Selectable Output Type
n Integrated Electronic Timer for Remote Headlight
Activation and Timed Turbo Cooldown
n Installer-Selectable Door Ajar/Delayed Courtesy Lights
n Prewired LED, Sensor and PlainView 2 Switch
Connectors
Seitenansicht 0
1 2 3 4 5 6 ... 13 14

Inhaltsverzeichnis

Seite 1 - System Components

Standard Features of the Concept 100*Programmable (+) or (-) require relays.System ComponentsThe Concept 100 installation kit contains the following c

Seite 2 - 2 Con cept 100/199

Installer-Programmable FeaturesTo access the installer-programmable features, use the procedure defined in the User-Programmable s ection, but after c

Seite 3 - Con cept 100/199 3

System Checklist & Troubleshooting (Continued)Step 3.Test the chirps.Close all doors and arm the Concept 100 by pressing the button on the remot

Seite 4

System Checklist & Troubleshooting (Continued)Step 5.Test the door locks.Arm the sys tem by press ing the button on the re mote con trol.nDoors

Seite 5 - Engine Bay Connections

System Checklist & Troubleshooting (Continued)Step 9.Test the dis arm func tion.nDisarm by pressing the button on the remote control. The follo

Seite 6 - SmartPowerUp™ 2

System Checklist & Troubleshooting (Continued)Step 14.Test the AutoArming By pass fea ture.Disarm the system. Turn the ignition to the “ON” posit

Seite 7 - Eight-Event TotalRecall

Wiring Description for the 4-Pin ConnectorPin Wire Color Con nects to1 Green/Blue Ignition Output2 White/Blue Starter Output3 White/Brown Ignition Inp

Seite 9 - User-Programmable Features

Passenger Compartment ConnectionsControl Unit and External ReceiverThe Concept 100 con trol unit must be in stalled in side the ve hi cle. Un der no c

Seite 10 - 10 Con cept 100/199

Passenger Compartment Connections (Continued)Trunk TriggerVehicles with a ground-switching trunk light will interface directly with the Concept 100 (o

Seite 11 - Con cept 100/199 11

Hood TriggerVehicles with a ground-switching hood light will interface directly with the Concept 100 (on positi ve switching Rolls-Royce vehicles, use

Seite 12

FACT—False Alarm Control and TestThe system microprocessor automatically checks for another activated sensor or trigger before sound ing the siren a s

Seite 13 - Con cept 100/199 13

Programmable FeaturesConcept 100 comes from the factory with its features preprogrammed as noted in bold text in the tables on pages 9 and 10. Somefea

Seite 14

User-Programmable FeaturesUser-Programmable Features (1 Chirp = OFF, 2 Chirps = ON)Fea tureSelectUnmarked 1 Unmarked 2 Unmarked 3 Unmarked 4✱ 1 Add N